| Specification: | AQ5000Pro IAQ Monitor Technical Specifications
Measured Parameters:
Carbon Dioxide:
* Detector NDIR (non-dispersive infrared)
* Range User Selectable
* 0 to 5,000 and 0 to 20,000 ppm
* Accuracy 0 to 5,000 ppm: +/-3% of reading +/-50 ppm
* 0 to 20,000 ppm: +/-3% of reading +/-300 ppm
Temperature Influence Additional +/-0.2% of reading
+/-2 ppm for each °C
* Resolution 1 ppm (10 ppm above 10,000 ppm)
* Response Time 22 seconds for 63% of final value; 70 seconds for 10-90% of 4000 ppm change
Relative Humidity:
* Detector Capacitive
* Range 0-100% non-condensing
* Accuracy +/-3% @ 25°C
* Resolution 0.1%
* Response Time 50 seconds with min air flow of 1 mi/hr
* (.45 meters/sec) through wand
Temperature:
* Detector Thermistor
* Range 0 to 60°C (+32 to +140°F)
* Accuracy +/-5°C (+/-0.9 °F) requires min air flow of 1 mi/hr (.45 meters/sec) through wand
* Resolution 0.1 oC
Dew Point:
* Range -65 °C/+60 °C
* Resolution 0.1 °C
Gas:
* Detector O2, CO, H2S, SO2, CL2, NO2, NO, HCN & NH3
* Resolution 0.1, 0.5 or 1 ppm depending on sensor in use
Air Velocity:
* Detector Hot-Wire
* Range 0-20 m/s
* Accuracy +/- 5%
* Resolution 0.1 m/s
Linear:
* Range +/-1 V
* Accuracy +/-2% of full scale
* Resolution 0.001 Vdc
Data Storage:
* 57,344 total samples
Display:
* 20 character x 4 lines backlit LCD
Real Time Clock:
* 0.01% accuracy
Storage Rate:
* 1 sec, 1 min, 5 min, 10 min or 15 min sample or averages
Statistics Saved:
* Up to 5 data values per sampling interval (CO2, temperature, humidity, dew point, gas and linear and air velocity input)
Communications:
* Format RS-232, 1 start, 8 data, 1 stop bit, no parity
* Baud Rate 1200 to 38400
Printer Output:
Summary Report includes:
* Separate reports for each logging session indicating minimum, maximum & time of occurrence, elapsed time & average per session.
* Gas readings include:
TWA & STEL
Time History Report Includes:
All recorded data values with date & time stamp
Power:
* Internal Power:
"AA" Alkaline Batteries - >15 hrs @ 25°C (77°F)
* Rechargeable NiMH Battery Pack: 7 hrs @ 25°C (77°F)
(Data Retention 30 days in the event of low battery)
* External Power:
+6.0 Vdc output AC power adapter, 120 VAC or 240v
Environments:
* Operating Temperature: 0 to +50°C (+32 to +122°F)
* Storage Temperature: -20 to +60°C (-4 to +140°F)
Size:
* Enclosure Size 3.6 x 7.1 x 1.3" (9.1 x 18.0 x 3.3 cm)
* Wand Size 11.8" (30cm) long, 1" (2.54 cm) diameter
Weight:
* 2 lbs. (0.83 kg) |